Complete probe set; insulated for hand-held equipment - IEC1010; attenuation: 1:1 or 1:10; attenuation: 1:1; bandwidth: DC to 15MHz; rise time: 2.7ns; input resistance: 1Mohm (input resistance scope); input capacitance: 46pF + cap. scope; working voltage: 600V DC incl. peak AC derating with frequency; attenuation: 1:10; bandwidth: DC to 60MHz; rise time: 5.5ns; input resistance: 10Mohm (if scope input = 1Mohm; input capacitance: 18pF approx.; working voltage: 600V DC incl. peak AC derating with frequency; compensation range: 10 to 35pF; cable length: 4.6ft; remarks: with insulated BNC connector.